TECHNICAL DATA:
- Total width: 200 mm
- Thickness: 80 mm
- Lengths: 195 cm / 245 cm / 265 cm / 290 cm / 330 cm / 360 cm / 390 cm / 450 cm
- Permissible bending moment (M): 5 kNm
- Permissible shear force (Q): 11 kN
- Material: spruce wood, grade C24 (PEFC)
- Web material: 3-layer panel, 27 mm thick
- Fittings: durable polymer plastic
- Finish / Coating: protective paint applied to the entire beam
- Weight per 1 linear meter: approx. 4.7 kg
- Certificate ÜZ-BWU03-l 14.24.29, certified by MPA Stuttgart in accordance with EN 13377 and DIN V 20000-2 standards
- C1 bonding certification in accordance with the DIN 1952-2008 standard
Sent to the email address provided in the order details
Shipping cost for the selected product
The shipping cost applies to this product (in the selected variant - if applicable). It may change after adding other products to the cart.
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Wybierz wariant produktu:
Individual variants may differ in price
Options
Share the product card
Description
H20 TIMBER BEAM (WITH PROTECTIVE END CAPS)
The H20 timber beam (with protective end caps) is a fundamental structural component designed for use in slab and wall formwork systems.
It is responsible for the safe transfer of loads generated by the concrete mix and for stiffening the entire formwork system.
The use of polymer-based end caps on the beam ends significantly increases the girder's resistance to mechanical damage, extending its service life and allowing for repeated use on subsequent construction sites.
Key advantages
- Reinforced ends (end caps): protect the edges against damage during use and transport.
- Three-layer construction: made of three layers of wood joined with finger joints along the entire length, ensuring high flexibility and long-term dimensional stability.
- Broad compatibility: works seamlessly with standard construction props, prop heads, and formwork panels.
- Reusable: durable construction designed for intensive use in construction site conditions.
Applications
- Slab formwork: used as primary beams (placed in prop heads) and secondary/distribution beams (laid transversely beneath formwork panels or plywood).
- Wall formwork and beam formwork: used as structural components for stiffening and supporting the pressure exerted by the concrete mix.
Frequently Asked Questions (FAQ)
1. What is the difference between a capped and an uncapped beam (girder)?
A capped beam features special protective covers (caps) made of durable polymer plastic at its ends; these effectively shield the timber structure from mechanical damage and delamination caused by impacts or during transport.
2. What accessories are used with H20 beams?
The beams are placed onto formwork heads mounted on slab props. A three-layer panel or formwork plywood is then laid across the top flange of the beams.
3. How should H20 beams be stored after work is completed?
To ensure the maximum service life of the beams, it is recommended to store them horizontally on wooden spacers, in a covered and well-ventilated area.